. Section 09650 PART 1. GENERAL 1.XX QUALITY ASSURANCE A. Standards: Meet requirements of Resilient Floor Covering Institute. B. Moisture Tests: Owner will employ services of an Independent Testing Laboratory (ITL) for testing the moisture content of concrete slabs in accordance with requirements of ASTM F l869-98, Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor using Anhydrous Calcium Chloride. 1.XX PROJECT/SITE CONDITIONS A. Environmental Requirements: Maintain room temperature and humidity levels before, during and after installation as required by flooring manufacturer. PART 3. EXECUTION 3.XX EXAMINATION A. Verify that concrete slab over vapor barrier meets moisture tests. B. Verify that finish floor tolerances meet requirements shown in Section 03300 Concrete. C. Do not proceed with installation until verifications indicate requirements are met. D. Notify Architect if verifications indicated non-compliance with Contract Documents.